Cool nights are on the way in Spring Hill and Columbia. Days can still feel like summer. That split is hard on a heat pump. The outdoor unit dumped heat all season. Soon it has to collect heat from damp Middle Tennessee air. The first thermostat call for heat is when a stuck reversing valve, a dead defrost control, or a quiet outdoor fan shows up.
Do not wait for a no-heat night. Eskimo Brothers Air Conditioning is a family shop. Join Our Family. Spring Hill jobs leave from 220 Town Center Pkwy Ste 140, Spring Hill, TN 37174. Columbia jobs leave from 610 N Garden St Basement, Columbia, TN 38401. One number for both offices: 931-682-6969. You reach the shop that rolls the truck. Not a call center.
Call Now 931-682-6969 · Text Now 931-682-6969
The reversing valve sat in cool all summer
A heat pump uses one circuit for both seasons. The reversing valve is the switch. In cool, it sends heat outdoors. In heat, it pulls heat from outdoor air and moves it inside.
That valve can sit in one position from spring through early fall. Then a 55-degree night hits the Duck River side of Columbia, or a new Spring Hill house on the Maury and Williamson County line. The thermostat asks for heat. The valve has to shift.
If it does not, supply air stays cool or barely warm. Electric heat strips can hide the failure for a night. Rooms warm. The bill jumps. That is strip heat, not a working heat pump.
A short dusty smell on first heat can be normal. It should fade in minutes. Cool air on a heat setting is not. A breaker that trips on first heat is not. Do not keep flipping heat and cool to “test” it. That can burn the solenoid.
We repair heat pumps as year-round systems. Furnace-only houses use our heating page.
Defrost on wet Maury and Williamson nights
Fall nights here are often wet. In heat mode, the outdoor coil can frost. A working heat pump runs a defrost cycle. It shifts for a few minutes and melts the frost. Steam off the cabinet is common. A brief whoosh of cooler air at the vents is common.
What is not normal: a solid block of ice that never clears. A unit stuck in defrost. A fan that will not spin. A bang every time it tries to shift. Those are defrost board, sensor, or reversing-valve faults.
Do not chip ice off the coil. You will cut a tube. Do not pour water over electrical parts. Turn the system off and call.
Run first heat this week while you are home
- Change a packed filter.
- Set heat a few degrees above room temperature.
- The outdoor unit should start. Supply air should warm within a few minutes. Heat-pump air is warm, not furnace-hot.
- If the fan sits still, the air stays cool, or only the strips click, stop and call.
- Pull leaves and toys off the outdoor unit.
We watch it reverse. We check the reversing valve, defrost control, outdoor sensors, backup heat, and the filter.
Free service call, free estimates, and free second opinions apply. Senior and military customers get 10% off repairs. New unit changeouts are 5% off. We do not add a night charge or a weekend charge.
Two offices, one 931 number
Franklin and Thompson’s Station jobs leave from Town Center Parkway in Spring Hill. Mount Pleasant and Santa Fe jobs leave from Garden Street in Columbia. Same family. Same phone.
Start at Home. Spring Hill dispatch lives on our Spring Hill HVAC page. Columbia dispatch lives on our Columbia HVAC page. Send a photo on Contact or email EskimoBrothersAir@gmail.com. Tell us the town and what the heat pump is doing.
Check it before nights cool off.
Call Now 931-682-6969 · Text Now 931-682-6969
FAQs
Why check a heat pump in fall in Spring Hill and Columbia?
Nights drop while days can still run warm. The unit has to reverse after a long cooling season. Fall is when we catch reversing valve, defrost, and first-heat problems before a no-heat night.
What is defrost on a heat pump?
In heat mode the outdoor coil can frost on cold, damp nights. A working defrost cycle thaws it. Steam for a few minutes can be normal. A solid block of ice that never clears is a failure. Call 931-682-6969.
What does a reversing valve do?
It switches the heat pump from cooling to heating. If it sticks, you can get cool or lukewarm air when you asked for heat. That is a repair diagnosis, not a thermostat guess.
Do both offices use the same number?
Yes. Spring Hill at 220 Town Center Pkwy Ste 140 and Columbia at 610 N Garden St Basement share 931-682-6969. Call or text. One family shop. Join Our Family.